WEBVTT

1
00:00:02.990 --> 00:00:09.260
Jamie, here's a question we get frequently,
here in the NVE Applications Center. 

2
00:00:09.260 --> 00:00:16.260
Working voltage for NVE isolators is 600 volts RMS
and transient overvoltage is 4000 volts peak.

3
00:00:18.730 --> 00:00:21.410
Yes, best in class.

4
00:00:21.410 --> 00:00:28.410
So, that's great for line-voltage applications.
But what voltage can they withstand continuously?

5
00:00:29.019 --> 00:00:35.370
The maximum voltage indefinitely across an
isolator is called endurance voltage. 

6
00:00:35.370 --> 00:00:41.010
It's not in most data sheets, and may be the least
familiar high-voltage specification. But it's

7
00:00:41.010 --> 00:00:48.010
useful in applications where the isolators
aren't subject to line voltage transients.

8
00:00:49.520 --> 00:00:56.080
IsoLoop endurance voltage is 1000 volts RMS
and 1500 volts DC.

9
00:00:56.080 --> 00:00:59.220
How do you test endurance?

10
00:00:59.220 --> 00:01:04.390
Endurance tests the isolation barrier. Our
extraordinary endurance comes from 

11
00:01:04.390 --> 00:01:11.390
a unique polymer/ceramic composite barrier.
Pins are tied together on each side.

12
00:01:11.679 --> 00:01:16.159
The endurance voltage is applied; and
we leave it like that for years.

13
00:01:16.159 --> 00:01:19.899
Years? How long is “indefinitely”?

14
00:01:19.899 --> 00:01:26.899
Our reliability data show an MTBF of 44000
years at the endurance voltage and 100 degrees C.

15
00:01:28.219 --> 00:01:33.020
So you've had parts on life test since the
Pleistocene era?

16
00:01:33.020 --> 00:01:39.280
Well, since the Clinton administration, with
standard FITs extrapolations.

17
00:01:39.280 --> 00:01:42.679
And where is “endurance voltage” important?

18
00:01:42.679 --> 00:01:49.679
Battery management systems come to mind.
In this circuit, the last isolation stage is

19
00:01:50.819 --> 00:01:57.819
300 volts above controller ground. So the
isolator sees 300 volts between supplies.

20
00:02:00.090 --> 00:02:06.979
But with an endurance voltage of 1500 volts DC,
it will easily withstand the voltages

21
00:02:06.979 --> 00:02:08.500
 in this circuit.

22
00:02:08.500 --> 00:02:12.420
And that endurance spec is for all packages?
Even MSOPs?

23
00:02:12.420 --> 00:02:18.200
You betcha. The unique IsoLoop MSOPs meet
that endurance spec.

24
00:02:18.200 --> 00:02:23.610
Well, thanks, Jamie. Where can I get more
info?

25
00:02:23.610 --> 00:02:30.610
Visit nve.com for application bulletins. Or
call us at 800-GMR-7141, extension 4.

