WEBVTT
Kind: captions
Language: en

00:00:00.000 --> 00:00:02.920
♪ Sensitivity...

00:00:02.920 --> 00:00:03.740
Hello.

00:00:03.740 --> 00:00:07.300
Today we're demonstrating
the AAL024,

00:00:07.300 --> 00:00:10.490
a remarkable new GMR sensor
for sensing current

00:00:10.490 --> 00:00:13.240
through circuit-board traces.

00:00:13.240 --> 00:00:16.080
GMR sensors are perfect
for current sensing

00:00:16.080 --> 00:00:19.920
because they're inherently isolated
with no insertion losses.

00:00:19.920 --> 00:00:22.020
And GMR sensors
are much more sensitive

00:00:22.020 --> 00:00:26.440
and lower noise
than Hall effect sensors.

00:00:26.440 --> 00:00:29.980
We'll demonstrate a board
you can buy on our Website.

00:00:29.980 --> 00:00:32.720
The board has four trace configurations:

00:00:32.740 --> 00:00:35.000
A trace on the bottom of the PCB,

00:00:35.010 --> 00:00:38.280
which provides excellent electrical isolation.

00:00:38.280 --> 00:00:41.010
Two configurations with
the sensor over a trace

00:00:41.010 --> 00:00:42.800
on the top-side of the board,

00:00:42.800 --> 00:00:46.700
and a more sensitive configuration
with five coil turns.

00:00:46.700 --> 00:00:49.809
We'll use the third section.

00:00:49.809 --> 00:00:51.969
The sensor is connected to
a nine-volt battery

00:00:51.969 --> 00:00:56.680
and an oscilloscope.

00:00:56.680 --> 00:00:59.320
An operational power supply
drives the trace,

00:00:59.320 --> 00:01:01.740
and a signal generator provides
a linear ramp

00:01:01.740 --> 00:01:05.239
to drive the current
from plus-to-minus five amps.

00:01:05.239 --> 00:01:08.850
So the X-axis
corresponds to the circuit-board current,

00:01:08.850 --> 00:01:18.099
and the Y-axis is the sensor output.

00:01:18.099 --> 00:01:20.539
The sensor output follows the current
very closely

00:01:20.539 --> 00:01:22.880
in the zero to two amp range.

00:01:22.880 --> 00:01:26.420
It's nonlinear but usable above that.

00:01:26.420 --> 00:01:31.139
The sensitivity works out to
10.7 millivolts per volt per amp.

00:01:31.139 --> 00:01:33.360
The typical sensitivity
for this configuration

00:01:33.360 --> 00:01:35.780
is 12 millivolts per volt per amp,

00:01:35.780 --> 00:01:39.900
and we're within the specification
tolerance of the sensor.

00:01:39.909 --> 00:01:46.420
Here's a summary for each configuration.

00:01:46.420 --> 00:01:50.740
GMR works so well because it's
sensitive IN the circuit-board plane,

00:01:50.740 --> 00:01:56.420
so the sensor goes over the trace, and
the sensing element is very close.

00:01:56.420 --> 00:02:01.579
And GMR is inherently low noise.

00:02:01.579 --> 00:02:05.380
Here's a typical Hall-effect configuration
for current sensing.

00:02:05.380 --> 00:02:10.679
Because of its odd direction of sensitivity,
the Hall sensor has to be next to the trace,

00:02:10.680 --> 00:02:11.960
rather than over it,

00:02:11.960 --> 00:02:16.500
which increases the spacing
and decreases the sensitivity.

00:02:16.500 --> 00:02:20.660
Hall sensors can be amplified,
but their noise is also amplified,

00:02:20.660 --> 00:02:24.460
and their detectivity is noise limited.

00:02:24.460 --> 00:02:28.040
GMR is nearly 50 times more sensitive.

00:02:28.040 --> 00:02:32.400
A Hall sensor produces 2 millivolts per amp
in a typical application,

00:02:32.400 --> 00:02:36.900
while our GMR sensor produces
90 millivolts per amp.

00:02:36.900 --> 00:02:42.860
GMR sensors also have negligible noise:
the equivalent of 0.005 amps,

00:02:42.870 --> 00:02:47.020
compared to 12 amps equivalent
for a Hall sensor.

00:02:47.020 --> 00:02:48.740
So to the "lab results" are in.

00:02:48.740 --> 00:02:52.120
GMR sensors are ideal for
current sensing.

00:02:52.120 --> 00:02:57.140
Also, because of their high sensitivity,
GMR sensors can easily interface directly

00:02:57.140 --> 00:02:58.560
to other circuits,

00:02:58.560 --> 00:03:04.760
or to inexpensive microcontrollers
with 10-bit A-to-D's.

00:03:04.760 --> 00:03:06.100
And they're small.

00:03:06.100 --> 00:03:13.180
The AAL024s we tested are in ultraminiature
two-and-a-half millimeter leadless packages.

00:03:13.180 --> 00:03:16.120
All this makes GMR sensors ideal for

00:03:16.120 --> 00:03:18.800
a number of current-sensing applications, including:

00:03:18.800 --> 00:03:20.060
motor controls,

00:03:20.060 --> 00:03:22.660
industrial control and factory automation,

00:03:22.660 --> 00:03:23.900
appliances,

00:03:23.900 --> 00:03:25.300
HVAC,

00:03:25.300 --> 00:03:28.720
and automotive.

00:03:28.720 --> 00:03:31.980
You can order parts or demo boards online,

00:03:32.520 --> 00:03:35.520
and we have a handy current-sensing Web app.
