WEBVTT
Kind: captions
Language: en

00:00:00.000 --> 00:00:08.100
♪ High voltage... ♪

00:00:08.100 --> 00:00:08.840
Hello.

00:00:08.940 --> 00:00:10.240
Today we're demonstrating

00:00:10.240 --> 00:00:14.780
an over-trace GMR current sensor 
in a simple isolated meter

00:00:14.780 --> 00:00:19.200
with no insertion loss.

00:00:19.680 --> 00:00:21.860
We're running this motor current
through a trace,

00:00:21.860 --> 00:00:24.340
under a sensor.

00:00:24.340 --> 00:00:27.600
Loading increases the current.

00:00:27.600 --> 00:00:29.240
There's virtually no load

00:00:29.240 --> 00:00:30.180
in series with the motor,

00:00:30.180 --> 00:00:32.540
so there are no resistive losses.

00:00:32.540 --> 00:00:35.691
And it's inherently isolated.

00:00:35.691 --> 00:00:37.230
You wouldn't want to touch
conventional meter terminals

00:00:37.230 --> 00:00:39.820
in a line-voltage circuit,

00:00:39.820 --> 00:00:43.580
but it's perfectly safe
with this sensor.

00:00:44.900 --> 00:00:46.940
Let's look at how it works.

00:00:46.940 --> 00:00:49.969
The sensor is over a trace
on the top-side of the board,

00:00:49.969 --> 00:00:54.860
from a section of a demo board
you can buy on our Website.

00:00:54.860 --> 00:00:57.809
The sensor detects the magnetic field

00:00:57.809 --> 00:01:02.260
created by the current
through the trace.

00:01:02.260 --> 00:01:05.370
This inexpensive meter
gives us three amps fullscale,

00:01:05.370 --> 00:01:09.300
or two amps RMS,
with a nine-volt supply.

00:01:09.300 --> 00:01:12.080
The sensor is "omnipolar,"
meaning it does inherent

00:01:12.080 --> 00:01:16.680
full-wave rectification.
and works for AC or DC.

00:01:16.680 --> 00:01:19.940
You can add a scaling resistor
for higher current ranges,

00:01:19.940 --> 00:01:22.980
and an offset adustment if needed.

00:01:23.240 --> 00:01:25.680
So we've shown that
GMR sensors can

00:01:25.680 --> 00:01:27.680
sense current through a trace

00:01:27.680 --> 00:01:29.580
with no insertion resistance,

00:01:29.580 --> 00:01:32.000
inherent isolation, and
enough signal

00:01:32.000 --> 00:01:35.080
to drive meters or circuitry
with no amplification.

00:01:36.740 --> 00:01:39.160
You can order parts or demo boards online,

00:01:39.540 --> 00:01:42.000
and we have a handy current-sensing Web app.
