AA and AB-Series Quick Reference
AA and AB-Series analog sensors include magnetometer,
gradiometer, angle sensing, and
current sensor configurations:
Magnetometers:
Part Number1 |
Linear Range
(|Oe2|)
|
Saturation
(|Oe|)
|
Sensitivity (mV/V-Oe)
|
Max. Non-Linearity
(% Uni.3)
|
Maximum Hysteresis
(% Uni.3) |
Max. Op. Temp.
(°C)
|
Typical
Resistance
|
Package
|
Min.
|
Max.
|
Min.
|
Max.
|
|
1.5
|
10.5
|
15
|
3.0
|
4.2
|
2
|
4
|
125
|
5 kΩ
|
SOIC8
|
|
2.0
|
14
|
20
|
2
|
3.2
|
2
|
4
|
125
|
5 kΩ
|
SOIC8
|
|
5.0
|
35
|
50
|
0.9
|
1.3
|
2
|
4
|
125
|
5 kΩ
|
MSOP8
|
|
5.0
|
35
|
50
|
0.9
|
1.3
|
2
|
4
|
125
|
5 kΩ
|
SOIC8
|
|
10.0
|
70
|
100
|
0.45
|
0.65
|
2
|
4
|
125
|
5 kΩ
|
SOIC8
|
|
5.0
|
35
|
50
|
0.9
|
1.3
|
2
|
4
|
125
|
30 kΩ
|
MSOP8
|
|
5.0
|
35
|
50
|
0.9
|
1.3
|
2
|
4
|
125
|
30 kΩ
|
SOIC8
|
|
0.6
|
3.0
|
6
|
7.5
|
13.0
|
4
|
15
|
150
|
2 kΩ
|
SOIC8
|
|
1.5
|
7.5
|
15
|
3.2
|
4.8
|
4
|
15
|
150
|
2 kΩ
|
MSOP8
|
|
1.5
|
10.5
|
15
|
3.0
|
4.2
|
2
|
2
|
150
|
5.5 kΩ
|
SOIC8
|
Gradiometers:
Part
Number1
|
Linear
Range
(|Oe2|)
|
Saturation
(|Oe|)
|
Element
Spacing
(mm)
|
Max. Non-
Linearity
(% Uni.3)
|
Maximum
Hysteresis
(% Uni.3) |
Max. Op.
Temp.
(°C)
|
Typical
Resistance
|
Package
|
Min.
|
Max.
|
|
20
|
200
|
250
|
0.5
|
2
|
4
|
125
|
2.5 kΩ
|
SOIC8
|
|
20
|
200
|
250
|
0.5
|
2
|
4
|
125
|
2.5 kΩ
|
MSOP8
|
|
5.0
|
40
|
70
|
0.5
|
4
|
15
|
150
|
1.2 kΩ
|
MSOP8
|
Angle Sensors:
Part
Number1
|
Typ. p-p
Signal
(mV/V)
|
Min. Applied
Field (Oe)
|
Max. Angular
Measurement
Error (const. field)
|
Max. Op.
Temp.
(°C)
|
Typical
Resistance
|
Package
|
|
200
|
30
|
0.5 degrees
|
125
|
1.25 MΩ
|
TDFN6
|
|
200
|
30
|
0.5 degrees
|
125
|
40 kΩ
|
TDFN6
|
|
200
|
30
|
0.5 degrees
|
125
|
6 MΩ
|
TDFN6
|
Current Sensors:
Part
Number1
|
Current
Measurement Range (mA)
|
Sensitivity
(mV/V/mA)
|
Max. Non-
Linearity
|
Max. Op.
Temp.
(°C)
|
Typical
Resistance
(Ohms)
|
Package
|
Min.
|
Max.
|
|
-80
|
80
|
0.08
|
1%
|
85
|
7 kΩ
|
TDFN6
|
Notes:
- Add "E" suffix for RoHS-compliant
versions.
- 1 Oersted (Oe) = 1 Gauss in air.
- Unipolar operation means exposure to magnetic fields
of one polarity, for example 0 to +30 Gauss, or -2 to
-50 Gauss. Bipolar operation (for example -5 to + 10
Gauss) increases nonlinearity and hysteresis
|